HYBRID solar INVERTER with charger
HYBRID INVERTER - WALL MOUNT
SP5000-SW/6000-SW/8000-SW/
11000-SW
The OPTI-Solar HYBRID INVERTER, a powerful all-in-one solution, delivers unsurpassed clean true sine wave output power combined with a selectable multistage battery charging current. The Hybrid/Off-Grid Inverter is suitable for any kind of applications such as air conditioner or any other home appliances, and its intelligent charger automatically charges any types of batteries without the risk of overcharge, while its compact & modular design makes installation easier and more cost efficient. This high quality product offers the best price/performance ratio in the industry.
MODEL | SP5000-SW | SP6000-SW | SP8000-SW | SP11000-SW | |
CAPACITY | |||||
VA / Watt | 5KVA/4000W | 6KVA/6000W | 8KVA/8000W | 11KVA/11000W | |
AC INPUT (FROM ARRAY) | |||||
Nominal Voltage | 120 Vac or 230 Vac | 230 Vac | |||
Voltage Range | Acceptable Voltage Range | 60~135 Vac or 120~270 Vac | 120~270 Vac | ||
Low Voltage Transfer | 60 Vac ±2% ; 120 Vac ±3% | 120 Vac ±2% | |||
Low Voltage Return | 65 Vac ±2% ; 130 Vac ±3% | 130 Vac ±2% | |||
High Voltage Transfer | 135 Vac ±% ; 270 Vac ±3% | 270 Vac ±2% | |||
High Voltage Return | 130 Vac ±2% ; 260 Vac ±3% | 260 Vac ±2% | |||
Frequency | 50Hz or 60Hz | ||||
DC INPUT (FROM ARRAY) | |||||
Nominal Voltage | 24V | 48V | |||
Charger Voltage | 27.6V | 55.2V | |||
Solar Maxmum Peak Voltage | 50V | 100V | |||
Start-up Voltage | 24V | 44V | |||
Polarity Protect | Yes | ||||
Backflow Protect | Yes | ||||
Maximum Charge Current | 40A | ||||
OUTPUT | |||||
Voltage | 110/115/120Vac | 220/230/240Vac | |||
220/230/240Vac | |||||
Voltage Regulation(Battery Mode) | <3% RMS for entire battery voltage range | ||||
Frequency Regulation | Line Mode | Synchronized to AC Main | |||
Battery Mode | 50Hz or 60Hz ±0.1Hz | ||||
Power Factor | 0.8 | 1 | |||
Wave Form | Pure Sine Wave | ||||
Overload Protection | Line Mode | >110%, then buzzer alarms and amber LED blinks continuously | |||
Battery Mode | 110%~150% for 30 sec ; >150% for 200ms | ||||
Short Circuit Protection | Line Mode | Circuit Breaker | |||
Battery Mode | Electronic Circuit | ||||
TRANSFER TIME | |||||
Typical | < 8 ms. | ||||
Battery Voltage | 24Vdc | 48Vdc | |||
Backup Time | Depends on system load and battery capacity (Base on the batteries connected) | ||||
Selectable Charging Current | Yes | ||||
DISPLAY | |||||
LCD | UPS status, I/P&O/P Voltage Frequency, Load Level, Battery Voltage & Level, Temperature, Model | ||||
LED | Normal (Green), Warning (Amber), Fault (Red) | ||||
AUDIBLE ALARM | |||||
Battery Mode | Beeping every 4 seconds | ||||
Low Battery | Beeping every second | ||||
UPS Fault | Beeping continuously | ||||
Overload | Beeping twice per second | ||||
ENVIRONMENT | |||||
Operation Temperature | 0-40°C ; 32-104°F | ||||
Relative Humidity | 0-95% non-condensing | ||||
Audible Noise | Less than 55dBA (at 1M) | ||||
PHYSICAL | |||||
Weight (Net / Gross Weight) | 49.2kgs / 63kgs | 51.4kgs / 66.6kgs | 53.6kgs / 67.7kgs | 94.6kgs / 110.4kgs | |
Dimensions (W×H×D) | 415×600×260mm | 415×600×260mm | 415×600×260mm | 452×670×277mm | |
ACCESSORY | |||||
RS232 or SNMP | Optional |